Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →When a fire strategy, inspection report or building control comment in Hove calls for glazing tested to resist fire, our fire-rated glazed doors service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
We supply and install glazed fire doorsets in timber, steel and aluminium, single and double, as stand-alone doors or within glazed screens. We match the door to the rating and duty of its position, and fit it to the manufacturer's installation instructions.
Survey visits can be arranged anywhere in Hove, including the BN3, BN88, BN50, BN41, BN1 districts, and in nearby Brighton, Portslade, Burgess Hill. Hove lies roughly 2 km from Brighton, within our East Sussex coverage.
Self-closing devices and correct gaps are part of the performance. We set them at installation and record them.
Doors that subdivide corridors and doors that swing both ways normally need vision panels, and integrity-only glass in doors may be limited by building guidance on escape routes.
Residential blocks in England over 11 metres need regular fire door checks under the Fire Safety (England) Regulations 2022; glazed doors are included.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
If an existing frame in a Hove building has no traceable evidence, we say so and price the options rather than guess.
After survey you get a fixed written quote for the agreed scope, so Hove budgets are not open-ended.
Sector guides below cover care homes, healthcare buildings and other buildings in Hove.
Yes. They need fire-resistant glass of the type and thickness tested, fitted with the specified beads and seals.
Cutting new apertures into a fire door is only acceptable when done under the door manufacturer's or certification scheme's instructions. Often a new doorset is the safer answer.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Hove confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.