Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →Fire-rated glazed doors in Derry / Londonderry is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.
Tell us what you need. We reply with next steps and a guide price.
We supply and install glazed fire doorsets in timber, steel and aluminium, single and double, as stand-alone doors or within glazed screens. We match the door to the rating and duty of its position, and fit it to the manufacturer's installation instructions.
Doors that subdivide corridors and doors that swing both ways normally need vision panels, and integrity-only glass in doors may be limited by building guidance on escape routes.
Opening forces, vision panel zones and contrast need to work with accessibility guidance as well as fire.
The safest route is a complete doorset with frame and hardware tested together. Mixing a leaf from one source with a frame from another needs evidence that covers the combination.
In Northern Ireland, building work follows the Building Regulations (Northern Ireland) 2012, with fire safety guidance in Technical Booklet E, approved by the district council's building control.
Once in use, the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 require the appropriate person to maintain fire safety measures, including fire-resisting glazing.
Technical Booklet E sets its own provisions for glazing on escape routes, so designs are checked against the Northern Ireland guidance rather than English documents.
Survey visits can be arranged anywhere in Derry / Londonderry, including the BT47, BT48 districts, and in nearby Coleraine, Omagh, Ballymena. Derry / Londonderry is the largest town in our County Londonderry coverage.
Every quote in Derry / Londonderry identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
You receive the classification references, glass marks and installation photographs for your fire safety records.
After survey you get a fixed written quote for the agreed scope, so Derry / Londonderry budgets are not open-ended.
We can survey and quote for offices, industrial units and other building types in Derry / Londonderry.
Yes, some steel, aluminium and timber doorsets are tested with large or full-height glazing. The glass must be the type and size in the evidence.
FD30 is a UK shorthand for a door providing 30 minutes' fire resistance. Under European classification the same door would be described with an E or EI rating, with S added where smoke control is tested.
Derry / Londonderry is in Northern Ireland, where the Building Regulations (NI) 2012 and Technical Booklet E apply, with the Fire Safety Regulations (NI) 2010 covering occupied premises.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We measure each opening in Derry / Londonderry and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.