Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →When a fire strategy, inspection report or building control comment in Newry calls for glazing tested to resist fire, our fire-rated glazed doors service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
A fire-rated glazed door is a fire door with substantial glass in it, from a large vision panel to a fully glazed leaf, supplied as a tested doorset or to a certificated specification. The glass, beads, seals, frame, hinges, closer and lock all form part of the rating.
Doors that subdivide corridors and doors that swing both ways normally need vision panels, and integrity-only glass in doors may be limited by building guidance on escape routes.
Opening forces, vision panel zones and contrast need to work with accessibility guidance as well as fire.
Each door design allows a maximum glazed area and aperture positions. Bigger glass needs a door tested for it.
Our County Down coverage takes in Newry (BT34) and the neighbouring towns of Portadown, Craigavon, Lisburn. Newry is about 69 km from Bangor, the largest town in our County Down coverage.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Every quote in Newry identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Newry building has no traceable evidence, we say so and price the options rather than guess.
In Northern Ireland, building work follows the Building Regulations (Northern Ireland) 2012, with fire safety guidance in Technical Booklet E, approved by the district council's building control.
Once in use, the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 require the appropriate person to maintain fire safety measures, including fire-resisting glazing.
Technical Booklet E sets its own provisions for glazing on escape routes, so designs are checked against the Northern Ireland guidance rather than English documents.
Sector guides below cover care homes, public buildings and other buildings in Newry.
Cutting new apertures into a fire door is only acceptable when done under the door manufacturer's or certification scheme's instructions. Often a new doorset is the safer answer.
FD30 is a UK shorthand for a door providing 30 minutes' fire resistance. Under European classification the same door would be described with an E or EI rating, with S added where smoke control is tested.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Glazed over-panels, side lights and borrowed lights around fire doors.
Learn more →Glazed screens and doors on protected stairs, lobbies and corridors.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We measure each opening in Newry and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.