Frameless Fire-Rated Glazing
Butt-jointed fire glass walls with minimal frames.
Learn more →We provide fire-rated glass partitions in Taunton and across Somerset, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass partitions are office-style glazed walls that are also tested to resist fire, used where a meeting room, corridor wall or reception wall forms part of a protected route or compartment. They look like standard office partitions but use rated frames, glass and seals throughout.
Rated partitions need fire-stopping inspected before ceilings close. We plan inspection points into the fit-out programme.
A fire-rated partition is only as good as the construction above it. If the wall has to run to the slab, the ceiling void needs fire-stopping or a rated head detail.
Demountable systems can be reconfigured, but moving a rated partition means rechecking its evidence and fire-stopping in the new position.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Whether the building is in central Taunton or the wider TA1, TA2 districts, we can survey and quote. We also cover Bridgwater, Burnham-on-Sea, Tiverton. Taunton lies roughly 65 km from Bath, within our Somerset coverage.
Every quote in Taunton identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
After survey you get a fixed written quote for the agreed scope, so Taunton budgets are not open-ended.
Fire-rated glass partitions applies to many building types in Taunton, including blocks of flats and care homes.
Frames may be slightly deeper and glass slightly thicker, but most systems are hard to tell apart from standard partitions.
Yes. We can supply and install the rated glazing package within a wider fit-out, working to your programme.
Building work in Taunton follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Survey timing in Taunton depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Butt-jointed fire glass walls with minimal frames.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
A survey in Taunton confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.