Frameless Fire-Rated Glazing
Butt-jointed fire glass walls with minimal frames.
Learn more →For Wimbledon buildings, we supply, replace and check fire-rated glass partitions wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Office fit-outs often only need fire-rated glazing on certain lines, such as corridors that serve as escape routes. We work from your fire strategy to rate only what needs rating, and match the look across the rest of the floor so the design stays consistent.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
You receive the classification references, glass marks and installation photographs for your fire safety records.
We can phase work in Wimbledon around residents, staff or pupils, with out-of-hours options.
Meeting rooms often need acoustic performance too. Some fire partition systems are tested for both; we confirm the combination.
Rated partitions need fire-stopping inspected before ceilings close. We plan inspection points into the fit-out programme.
Demountable systems can be reconfigured, but moving a rated partition means rechecking its evidence and fire-stopping in the new position.
Whether the building is in central Wimbledon or the wider SW19, SW20, SW18, SM4, SW17, SW15 districts, we can survey and quote. We also cover Morden, Mitcham, Putney. Wimbledon sits within our Greater London coverage, alongside Morden.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We can survey and quote for student accommodation, public buildings and other building types in Wimbledon.
Only where the fire strategy says the wall is fire-resisting, for example along a protected escape corridor or a compartment line. Many meeting room walls do not need a rating.
Some butt-jointed systems are tested for fire. See our frameless fire-rated glazing service for what is possible.
Yes. We survey and install in Wimbledon and across Greater London, including the SW19 district and nearby Morden.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Butt-jointed fire glass walls with minimal frames.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Wimbledon to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.