Frameless Fire-Rated Glazing
Butt-jointed fire glass walls with minimal frames.
Learn more →For Cricklewood buildings, we supply, replace and check fire-rated glass partitions wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass partitions are office-style glazed walls that are also tested to resist fire, used where a meeting room, corridor wall or reception wall forms part of a protected route or compartment. They look like standard office partitions but use rated frames, glass and seals throughout.
A fire-rated partition is only as good as the construction above it. If the wall has to run to the slab, the ceiling void needs fire-stopping or a rated head detail.
Demountable systems can be reconfigured, but moving a rated partition means rechecking its evidence and fire-stopping in the new position.
Meeting rooms often need acoustic performance too. Some fire partition systems are tested for both; we confirm the combination.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Survey visits can be arranged anywhere in Cricklewood, including the NW2, NW6, NW11, NW10, NW3, W10 districts, and in nearby Kilburn, Willesden, Chalk Farm. Cricklewood is one of the Greater London districts we cover.
We can phase work in Cricklewood around residents, staff or pupils, with out-of-hours options.
Every quote in Cricklewood identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Cricklewood building has no traceable evidence, we say so and price the options rather than guess.
Fire-rated glass partitions applies to many building types in Cricklewood, including hotels and schools and colleges.
Only where the fire strategy says the wall is fire-resisting, for example along a protected escape corridor or a compartment line. Many meeting room walls do not need a rating.
Frames may be slightly deeper and glass slightly thicker, but most systems are hard to tell apart from standard partitions.
Building work in Cricklewood follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We survey and install in Cricklewood and across Greater London, including the NW2 district and nearby Kilburn.
Butt-jointed fire glass walls with minimal frames.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Cricklewood to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.