Frameless Fire-Rated Glazing
Butt-jointed fire glass walls with minimal frames.
Learn more →For Witham buildings, we supply, replace and check fire-rated glass partitions wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Office fit-outs often only need fire-rated glazing on certain lines, such as corridors that serve as escape routes. We work from your fire strategy to rate only what needs rating, and match the look across the rest of the floor so the design stays consistent.
Non-rated partitions on the same floor can be matched in profile and finish.
Rated partitions need fire-stopping inspected before ceilings close. We plan inspection points into the fit-out programme.
Large glass walls need manifestation so people can see them. Applied film must be compatible with the glass and not cover any marks building control may need to see.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Whether the building is in central Witham or the wider CM8 districts, we can survey and quote. We also cover Maldon, Braintree, Chelmsford. Witham is about 30 km from Southend-on-Sea, the largest town in our Essex coverage.
Every quote in Witham identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Witham around residents, staff or pupils, with out-of-hours options.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
We can survey and quote for industrial units, offices and other building types in Witham.
Only where the fire strategy says the wall is fire-resisting, for example along a protected escape corridor or a compartment line. Many meeting room walls do not need a rating.
Frames may be slightly deeper and glass slightly thicker, but most systems are hard to tell apart from standard partitions.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Building work in Witham follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Butt-jointed fire glass walls with minimal frames.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Witham and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.