Frameless Fire-Rated Glazing
Butt-jointed fire glass walls with minimal frames.
Learn more →Fire-rated glass partitions in Eastbourne is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass partitions are office-style glazed walls that are also tested to resist fire, used where a meeting room, corridor wall or reception wall forms part of a protected route or compartment. They look like standard office partitions but use rated frames, glass and seals throughout.
Whether the building is in central Eastbourne or the wider BN21, BN22, BN20, BN23 districts, we can survey and quote. We also cover Hailsham, Seaford, Bexhill-on-Sea. Eastbourne lies roughly 31 km from Brighton, within our East Sussex coverage.
Meeting rooms often need acoustic performance too. Some fire partition systems are tested for both; we confirm the combination.
Rated partitions need fire-stopping inspected before ceilings close. We plan inspection points into the fit-out programme.
A fire-rated partition is only as good as the construction above it. If the wall has to run to the slab, the ceiling void needs fire-stopping or a rated head detail.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We can phase work in Eastbourne around residents, staff or pupils, with out-of-hours options.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Every quote in Eastbourne identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can survey and quote for retail and leisure units, blocks of flats and other building types in Eastbourne.
Frames may be slightly deeper and glass slightly thicker, but most systems are hard to tell apart from standard partitions.
Yes. We can supply and install the rated glazing package within a wider fit-out, working to your programme.
Building work in Eastbourne follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Butt-jointed fire glass walls with minimal frames.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Eastbourne and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.