Frameless Fire-Rated Glazing
Butt-jointed fire glass walls with minimal frames.
Learn more →Our fire-rated glass partitions service covers Earley and neighbouring areas such as Reading and Wokingham, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass partitions are office-style glazed walls that are also tested to resist fire, used where a meeting room, corridor wall or reception wall forms part of a protected route or compartment. They look like standard office partitions but use rated frames, glass and seals throughout.
Large glass walls need manifestation so people can see them. Applied film must be compatible with the glass and not cover any marks building control may need to see.
Rated partitions need fire-stopping inspected before ceilings close. We plan inspection points into the fit-out programme.
Meeting rooms often need acoustic performance too. Some fire partition systems are tested for both; we confirm the combination.
Coverage around Earley includes the RG6, RG2, RG41, RG5, RG1 districts and nearby Reading, Wokingham, Crowthorne. Earley is about 5 km from Reading, the largest town in our Berkshire coverage.
You receive the classification references, glass marks and installation photographs for your fire safety records.
We can phase work in Earley around residents, staff or pupils, with out-of-hours options.
Every quote in Earley identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Fire-rated glass partitions applies to many building types in Earley, including retail and leisure units and offices.
Yes. We can supply and install the rated glazing package within a wider fit-out, working to your programme.
Only where the fire strategy says the wall is fire-resisting, for example along a protected escape corridor or a compartment line. Many meeting room walls do not need a rating.
Yes. We survey and install in Earley and across Berkshire, including the RG6 district and nearby Reading.
Building work in Earley follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Butt-jointed fire glass walls with minimal frames.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Earley and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.