Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Our fire-rated glass floors service covers Burgess Hill and neighbouring areas such as Haywards Heath and Portslade, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass floors and horizontal rooflights are specialist systems with limited sizes and tested frames. We supply and install them where the evidence matches your span, load and rating, and coordinate the structural support with your engineer.
Whether the building is in central Burgess Hill or the wider RH15, BN6 districts, we can survey and quote. We also cover Haywards Heath, Portslade, Hove. Burgess Hill lies roughly 18 km from Crawley, within our West Sussex coverage.
Horizontal glazing in a fire-rated roof or floor behaves differently from a wall, so wall glass cannot simply be laid flat.
A glass floor must carry its design load during the fire period. Only systems tested for both should be used.
Walk-on glass needs an anti-slip finish; it must be one covered by the system.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
After survey you get a fixed written quote for the agreed scope, so Burgess Hill budgets are not open-ended.
We can phase work in Burgess Hill around residents, staff or pupils, with out-of-hours options.
Every quote in Burgess Hill identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Sector guides below cover care homes, offices and other buildings in Burgess Hill.
Yes, with clear glass and an anti-slip finish, or obscured if privacy is needed.
Yes, using specialist tested systems that cover load-bearing capacity as well as integrity and insulation.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Building work in Burgess Hill follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Burgess Hill to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.