Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →For South Shields buildings, we supply, replace and check fire-rated glass floors wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
A fire-rated glass floor is a walk-on glazed floor panel, set in a tested support frame, that keeps both its load-bearing capacity and its fire resistance for a stated time. Because a floor carries load, its classification also includes R for load-bearing capacity alongside integrity and insulation.
Survey visits can be arranged anywhere in South Shields, including the NE33, NE29, NE30, NE34, NE32 districts, and in nearby Tynemouth, North Shields, Jarrow. South Shields lies roughly 12 km from Newcastle upon Tyne, within our Tyne and Wear coverage.
Horizontal glazing in a fire-rated roof or floor behaves differently from a wall, so wall glass cannot simply be laid flat.
Walk-on glass needs an anti-slip finish; it must be one covered by the system.
A glass floor must carry its design load during the fire period. Only systems tested for both should be used.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
You receive the classification references, glass marks and installation photographs for your fire safety records.
If an existing frame in a South Shields building has no traceable evidence, we say so and price the options rather than guess.
After survey you get a fixed written quote for the agreed scope, so South Shields budgets are not open-ended.
We can survey and quote for healthcare buildings, offices and other building types in South Shields.
Yes, with clear glass and an anti-slip finish, or obscured if privacy is needed.
Yes, using specialist tested systems that cover load-bearing capacity as well as integrity and insulation.
Yes. We survey and install in South Shields and across Tyne and Wear, including the NE33 district and nearby Tynemouth.
Building work in South Shields follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
A survey in South Shields confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.