Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Fire-rated glass floors in Newcastle upon Tyne is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.
Tell us what you need. We reply with next steps and a guide price.
A fire-rated glass floor is a walk-on glazed floor panel, set in a tested support frame, that keeps both its load-bearing capacity and its fire resistance for a stated time. Because a floor carries load, its classification also includes R for load-bearing capacity alongside integrity and insulation.
A glass floor must carry its design load during the fire period. Only systems tested for both should be used.
Horizontal glazing in a fire-rated roof or floor behaves differently from a wall, so wall glass cannot simply be laid flat.
Tested floor panels have maximum spans. Larger openings are divided by a supporting grid.
Our Tyne and Wear coverage takes in Newcastle upon Tyne (NE1, NE8, NE4, NE2, NE6, NE10) and the neighbouring towns of Gateshead, Gosforth, Felling. Newcastle upon Tyne is the main town we cover in Tyne and Wear.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
You receive the classification references, glass marks and installation photographs for your fire safety records.
After survey you get a fixed written quote for the agreed scope, so Newcastle upon Tyne budgets are not open-ended.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover schools and colleges, blocks of flats and other buildings in Newcastle upon Tyne.
Yes, using specialist tested systems that cover load-bearing capacity as well as integrity and insulation.
Each system sets maximum panel sizes; larger areas are divided by a supporting grid.
Survey timing in Newcastle upon Tyne depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Newcastle upon Tyne and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.