Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →For Shrewsbury buildings, we supply, replace and check fire-rated glass floors wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass floors and horizontal rooflights are specialist systems with limited sizes and tested frames. We supply and install them where the evidence matches your span, load and rating, and coordinate the structural support with your engineer.
Coverage around Shrewsbury includes the SY1, SY2, SY3 districts and nearby Wellington, Telford, Rhosllannerchrugog. Shrewsbury lies roughly 21 km from Telford, within our Shropshire coverage.
Glass floors are made to order with longer lead times; we plan early with your contractor.
Walk-on glass needs an anti-slip finish; it must be one covered by the system.
A glass floor must carry its design load during the fire period. Only systems tested for both should be used.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Every quote in Shrewsbury identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Shrewsbury building has no traceable evidence, we say so and price the options rather than guess.
Sector guides below cover care homes, offices and other buildings in Shrewsbury.
Yes, using specialist tested systems that cover load-bearing capacity as well as integrity and insulation.
R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.
Survey timing in Shrewsbury depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Building work in Shrewsbury follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Shrewsbury and check what the existing frames can accept.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.