Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →From the NN11 district outwards, we arrange fire-rated glass floors for buildings across Daventry, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass floors and horizontal rooflights are specialist systems with limited sizes and tested frames. We supply and install them where the evidence matches your span, load and rating, and coordinate the structural support with your engineer.
We cover Daventry and the surrounding postcode districts, including NN11. Nearby towns we also serve include Rugby, Northampton, Royal Leamington Spa. Daventry lies roughly 19 km from Northampton, within our Northamptonshire coverage.
Glass floors are made to order with longer lead times; we plan early with your contractor.
Tested floor panels have maximum spans. Larger openings are divided by a supporting grid.
A glass floor must carry its design load during the fire period. Only systems tested for both should be used.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Every quote in Daventry identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Daventry around residents, staff or pupils, with out-of-hours options.
After survey you get a fixed written quote for the agreed scope, so Daventry budgets are not open-ended.
Sector guides below cover retail and leisure units, blocks of flats and other buildings in Daventry.
Each system sets maximum panel sizes; larger areas are divided by a supporting grid.
R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.
Survey timing in Daventry depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Daventry confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.