Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Leicestershire · LE2

Fire-Rated Glass Floors in Oadby, Leicestershire

For Oadby buildings, we supply, replace and check fire-rated glass floors wherever the fire strategy depends on it, working to the tested system rather than the glass alone.

REI 30 – 60LE2England

Quote for Oadby

Tell us what you need. We reply with next steps and a guide price.

What our fire-rated glass floors service includes in Oadby

Fire-rated glass floors and horizontal rooflights are specialist systems with limited sizes and tested frames. We supply and install them where the evidence matches your span, load and rating, and coordinate the structural support with your engineer.

  • Horizontal fire-rated rooflights
  • Steel support frames to the tested details
  • Coordination with the structural engineer
  • Tested walk-on fire-rated glass floor systems

Oadby coverage and nearby towns

Whether the building is in central Oadby or the wider LE2, LE18, LE5, LE1 districts, we can survey and quote. We also cover Wigston, Leicester, Market Harborough. Oadby lies roughly 5 km from Leicester, within our Leicestershire coverage.

Key checks for Oadby projects

Sizes are limited

Tested floor panels have maximum spans. Larger openings are divided by a supporting grid.

Slip resistance

Walk-on glass needs an anti-slip finish; it must be one covered by the system.

Programme

Glass floors are made to order with longer lead times; we plan early with your contractor.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

How we work in Oadby

Honest about unknowns

If an existing frame in a Oadby building has no traceable evidence, we say so and price the options rather than guess.

Work around occupied buildings

We can phase work in Oadby around residents, staff or pupils, with out-of-hours options.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Oadby building types

Sector guides below cover schools and colleges, industrial units and other buildings in Oadby.

Fire-Rated Glass Floors: Oadby questions

Can we see through it?

Yes, with clear glass and an anti-slip finish, or obscured if privacy is needed.

What does REI mean?

R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.

Do you work on occupied buildings in Oadby?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Can you price fire-rated glass floors in Oadby from photos?

We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.

Related

Related services in Oadby

E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
Process

From enquiry to handover in Oadby

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Measure and check

We measure each opening in Oadby and check what the existing frames can accept.

Written quote

You receive a written quote naming the tested system and classification.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote