Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · CR4

Mitcham fire-rated glass floors

Fire-rated glass floors in Mitcham is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.

REI 30 – 60CR4England

Quote for Mitcham

Tell us what you need. We reply with next steps and a guide price.

What's involved with fire-rated glass floors in Mitcham

Fire-rated glass floors and horizontal rooflights are specialist systems with limited sizes and tested frames. We supply and install them where the evidence matches your span, load and rating, and coordinate the structural support with your engineer.

  • Anti-slip surface treatments within the system
  • Steel support frames to the tested details
  • Coordination with the structural engineer
  • Tested walk-on fire-rated glass floor systems

What to check before ordering fire-rated glass floors in Mitcham

Load and fire together

A glass floor must carry its design load during the fire period. Only systems tested for both should be used.

Slip resistance

Walk-on glass needs an anti-slip finish; it must be one covered by the system.

Privacy

Obscured or patterned surfaces can be specified within the system for privacy below.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Mitcham coverage and nearby towns

Survey visits can be arranged anywhere in Mitcham, including the CR4, SM4, SW19, SW17, SW16, SM5 districts, and in nearby Morden, Wimbledon, Streatham. Mitcham is one of the Greater London districts we cover.

What every Mitcham quote includes

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

Work around occupied buildings

We can phase work in Mitcham around residents, staff or pupils, with out-of-hours options.

Rated systems, not just rated glass

Every quote in Mitcham identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Mitcham building types

Sector guides below cover hotels, public buildings and other buildings in Mitcham.

Fire-Rated Glass Floors: Mitcham questions

Can we see through it?

Yes, with clear glass and an anti-slip finish, or obscured if privacy is needed.

How big can a fire-rated glass floor panel be?

Each system sets maximum panel sizes; larger areas are divided by a supporting grid.

Do you carry out fire-rated glass floors in Mitcham?

Yes. We survey and install in Mitcham and across Greater London, including the CR4 district and nearby Morden.

Can you price fire-rated glass floors in Mitcham from photos?

We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.

Related

Related services in Mitcham

E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
Process

What happens next

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Survey

We visit Mitcham to measure, record existing marks and check the frames and substrate.

Written quote

You receive a written quote naming the tested system and classification.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote