Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →If a building in Highbury needs fire-rated glass floors, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass floors and horizontal rooflights are specialist systems with limited sizes and tested frames. We supply and install them where the evidence matches your span, load and rating, and coordinate the structural support with your engineer.
Walk-on glass needs an anti-slip finish; it must be one covered by the system.
Tested floor panels have maximum spans. Larger openings are divided by a supporting grid.
Obscured or patterned surfaces can be specified within the system for privacy below.
Our Greater London coverage takes in Highbury (N5, N7, N1, EC50, N1C, N4) and the neighbouring towns of Islington, Holloway, Stamford Hill. We cover Highbury as part of our Greater London coverage.
Every quote in Highbury identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Highbury budgets are not open-ended.
If an existing frame in a Highbury building has no traceable evidence, we say so and price the options rather than guess.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Fire-rated glass floors applies to many building types in Highbury, including schools and colleges and public buildings.
R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.
Yes, with clear glass and an anti-slip finish, or obscured if privacy is needed.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Highbury to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.