Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Our fire-rated glass floors service covers Dagenham and neighbouring areas such as Becontree and Romford, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
A fire-rated glass floor is a walk-on glazed floor panel, set in a tested support frame, that keeps both its load-bearing capacity and its fire resistance for a stated time. Because a floor carries load, its classification also includes R for load-bearing capacity alongside integrity and insulation.
Coverage around Dagenham includes the RM10, RM7, RM8, RM9, RM12, RM1 districts and nearby Becontree, Romford, Hornchurch. Dagenham sits within our Greater London coverage, alongside Becontree.
Horizontal glazing in a fire-rated roof or floor behaves differently from a wall, so wall glass cannot simply be laid flat.
A glass floor must carry its design load during the fire period. Only systems tested for both should be used.
Tested floor panels have maximum spans. Larger openings are divided by a supporting grid.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Every quote in Dagenham identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Dagenham around residents, staff or pupils, with out-of-hours options.
You receive the classification references, glass marks and installation photographs for your fire safety records.
We can survey and quote for healthcare buildings, hotels and other building types in Dagenham.
R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.
Yes, using specialist tested systems that cover load-bearing capacity as well as integrity and insulation.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Survey timing in Dagenham depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Dagenham and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.