Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →We provide fire-rated glass floors in Musselburgh and across Edinburgh and the Lothians, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass floors and horizontal rooflights are specialist systems with limited sizes and tested frames. We supply and install them where the evidence matches your span, load and rating, and coordinate the structural support with your engineer.
Glass floors are made to order with longer lead times; we plan early with your contractor.
A glass floor must carry its design load during the fire period. Only systems tested for both should be used.
Tested floor panels have maximum spans. Larger openings are divided by a supporting grid.
Coverage around Musselburgh includes the EH21, EH15, EH22 districts and nearby Edinburgh, Kirkcaldy, Glenrothes. Edinburgh, around 9 km from Musselburgh, is the largest town in the same coverage area.
Every quote in Musselburgh identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Musselburgh budgets are not open-ended.
Designs follow the building and fire safety rules that apply in Scotland, not a one-size-fits-all approach.
In Scotland, building work needs a building warrant under the Building (Scotland) Regulations 2004, with fire guidance in Section 2 of the Building Standards Technical Handbooks rather than Approved Documents.
For relevant premises, the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 place duties on the duty holder to maintain fire safety measures, which include fire-resisting glazing.
Scottish guidance has its own approach to escape routes and compartmentation, so glazing designs are checked against the Technical Handbooks and the warrant drawings.
Sector guides below cover schools and colleges, retail and leisure units and other buildings in Musselburgh.
R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.
Yes, with clear glass and an anti-slip finish, or obscured if privacy is needed.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Yes. We survey and install in Musselburgh and across Edinburgh and the Lothians, including the EH21 district and nearby Edinburgh.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Musselburgh confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.