Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →From the DE75 district outwards, we arrange fire-rated glass floors for buildings across Heanor, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
A fire-rated glass floor is a walk-on glazed floor panel, set in a tested support frame, that keeps both its load-bearing capacity and its fire resistance for a stated time. Because a floor carries load, its classification also includes R for load-bearing capacity alongside integrity and insulation.
Tested floor panels have maximum spans. Larger openings are divided by a supporting grid.
Obscured or patterned surfaces can be specified within the system for privacy below.
Glass floors are made to order with longer lead times; we plan early with your contractor.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Survey visits can be arranged anywhere in Heanor, including the DE75, NG16, DE5 districts, and in nearby Ripley, Ilkeston, Belper. Heanor lies roughly 13 km from Derby, within our Derbyshire coverage.
If an existing frame in a Heanor building has no traceable evidence, we say so and price the options rather than guess.
After survey you get a fixed written quote for the agreed scope, so Heanor budgets are not open-ended.
Every quote in Heanor identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can survey and quote for retail and leisure units, offices and other building types in Heanor.
Each system sets maximum panel sizes; larger areas are divided by a supporting grid.
Yes, with clear glass and an anti-slip finish, or obscured if privacy is needed.
Yes. We survey and install in Heanor and across Derbyshire, including the DE75 district and nearby Ripley.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit Heanor to measure, record existing marks and check the frames and substrate.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.