Insulated Fire Glass (EI)
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Our fire-rated glass floors service covers Billingham and neighbouring areas such as Stockton-on-Tees and Middlesbrough, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated glass floors and horizontal rooflights are specialist systems with limited sizes and tested frames. We supply and install them where the evidence matches your span, load and rating, and coordinate the structural support with your engineer.
Glass floors are made to order with longer lead times; we plan early with your contractor.
A glass floor must carry its design load during the fire period. Only systems tested for both should be used.
Horizontal glazing in a fire-rated roof or floor behaves differently from a wall, so wall glass cannot simply be laid flat.
Coverage around Billingham includes the TS23, TS20, TS19, TS18, TS1, TS4 districts and nearby Stockton-on-Tees, Middlesbrough, Thornaby-on-Tees. Billingham is about 18 km from Darlington, the largest town in our County Durham coverage.
Every quote in Billingham identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can phase work in Billingham around residents, staff or pupils, with out-of-hours options.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Fire-rated glass floors applies to many building types in Billingham, including offices and care homes.
R is load-bearing capacity, E is integrity and I is insulation. A floor needs R because it carries people and loads.
Each system sets maximum panel sizes; larger areas are divided by a supporting grid.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Yes. We survey and install in Billingham and across County Durham, including the TS23 district and nearby Stockton-on-Tees.
EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Slim steel frames for long spans, high ratings and heavy glass.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Billingham confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.