Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →Looking for frameless fire-rated glazing in Littlehampton? We survey, supply and install tested fire-rated glazing for industrial units, hotels and other buildings in and around Littlehampton, including the BN17 postcode district.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire glazing only works within tight, tested limits: specific glass types, joint widths, sealants, channel details and maximum heights. We specify it where the evidence supports your layout, and tell you plainly when a slim framed system is the better route.
The sealant, joint width and any interlayer in the joint come from the test. Generic silicone in a fire glass joint is not acceptable.
Channels at the head have to allow for slab movement without loading the glass.
Frameless glass is exposed during the build. We plan protection until other trades finish.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Whether the building is in central Littlehampton or the wider BN17, BN16 districts, we can survey and quote. We also cover Bognor Regis, Worthing, Chichester. Littlehampton lies roughly 42 km from Crawley, within our West Sussex coverage.
Every quote in Littlehampton identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Littlehampton budgets are not open-ended.
If an existing frame in a Littlehampton building has no traceable evidence, we say so and price the options rather than guess.
Sector guides below cover industrial units, hotels and other buildings in Littlehampton.
Yes, typically. It also needs more careful site protection.
Each system states a maximum height. We check your floor-to-ceiling height against it during design.
Survey timing in Littlehampton depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Building work in Littlehampton follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Littlehampton and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.