Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →For Kingswinford buildings, we supply, replace and check frameless fire-rated glazing wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire-rated glazing is a glass wall where panes meet edge to edge with a tested sealant joint instead of vertical frames, held in discreet head and base channels. It gives an almost uninterrupted view while still being tested to resist fire.
Frameless glass is exposed during the build. We plan protection until other trades finish.
Maximum heights and the ability to form corners vary by system. Corners may need a post or a specific tested joint.
The sealant, joint width and any interlayer in the joint come from the test. Generic silicone in a fire glass joint is not acceptable.
We cover Kingswinford and the surrounding postcode districts, including DY6, DY3, DY5, DY8. Nearby towns we also serve include Brierley Hill, Stourbridge, Dudley. Birmingham, around 18 km from Kingswinford, is the largest town in the same coverage area.
After survey you get a fixed written quote for the agreed scope, so Kingswinford budgets are not open-ended.
Every quote in Kingswinford identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Kingswinford building has no traceable evidence, we say so and price the options rather than guess.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Sector guides below cover industrial units, retail and leisure units and other buildings in Kingswinford.
Yes, using tested butt-jointed systems, usually with insulating glass. It must be installed exactly to the tested details.
Usually through a slim framed door set into the run, chosen so the combination is covered by evidence.
Building work in Kingswinford follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Kingswinford and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.