Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →If a building in Newburn needs frameless fire-rated glazing, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire glazing only works within tight, tested limits: specific glass types, joint widths, sealants, channel details and maximum heights. We specify it where the evidence supports your layout, and tell you plainly when a slim framed system is the better route.
The sealant, joint width and any interlayer in the joint come from the test. Generic silicone in a fire glass joint is not acceptable.
Maximum heights and the ability to form corners vary by system. Corners may need a post or a specific tested joint.
Frameless fire glazing is at the top of the price range because of the glass and precision required.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Survey visits can be arranged anywhere in Newburn, including the NE15, NE40, NE21, NE5 districts, and in nearby Gosforth, Newcastle upon Tyne, Gateshead. Newburn is about 8 km from Newcastle upon Tyne, the largest town in our Tyne and Wear coverage.
After survey you get a fixed written quote for the agreed scope, so Newburn budgets are not open-ended.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
If an existing frame in a Newburn building has no traceable evidence, we say so and price the options rather than guess.
Sector guides below cover offices, blocks of flats and other buildings in Newburn.
Usually through a slim framed door set into the run, chosen so the combination is covered by evidence.
Yes, using tested butt-jointed systems, usually with insulating glass. It must be installed exactly to the tested details.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Building work in Newburn follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Newburn to measure, record existing marks and check the frames and substrate.
We set out the system, glass, evidence and programme, with a fixed price.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.