Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →For Newcastle-under-Lyme buildings, we supply, replace and check frameless fire-rated glazing wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire-rated glazing is a glass wall where panes meet edge to edge with a tested sealant joint instead of vertical frames, held in discreet head and base channels. It gives an almost uninterrupted view while still being tested to resist fire.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
If an existing frame in a Newcastle-under-Lyme building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Newcastle-under-Lyme identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Frameless fire glazing is at the top of the price range because of the glass and precision required.
True frameless fire doors are rare; most frameless walls use a slim framed door within the run. We show you the options on drawings.
Frameless glass is exposed during the build. We plan protection until other trades finish.
We cover Newcastle-under-Lyme and the surrounding postcode districts, including ST5, ST4, ST1. Nearby towns we also serve include Stoke-on-Trent, Longton, Kidsgrove. Stoke-on-Trent, around 3 km from Newcastle-under-Lyme, is the largest town in the same coverage area.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We can survey and quote for healthcare buildings, retail and leisure units and other building types in Newcastle-under-Lyme.
Yes, using tested butt-jointed systems, usually with insulating glass. It must be installed exactly to the tested details.
Usually through a slim framed door set into the run, chosen so the combination is covered by evidence.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Survey timing in Newcastle-under-Lyme depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Newcastle-under-Lyme confirms sizes, access, existing evidence and fixing conditions.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.