Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →For Nelson buildings, we supply, replace and check frameless fire-rated glazing wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire glazing only works within tight, tested limits: specific glass types, joint widths, sealants, channel details and maximum heights. We specify it where the evidence supports your layout, and tell you plainly when a slim framed system is the better route.
Frameless fire glazing is at the top of the price range because of the glass and precision required.
Frameless glass is exposed during the build. We plan protection until other trades finish.
True frameless fire doors are rare; most frameless walls use a slim framed door within the run. We show you the options on drawings.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Whether the building is in central Nelson or the wider BB9, BB8, BB10 districts, we can survey and quote. We also cover Colne, Burnley, Accrington. Nelson lies roughly 34 km from Preston, within our Lancashire coverage.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
If an existing frame in a Nelson building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Nelson identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can survey and quote for blocks of flats, industrial units and other building types in Nelson.
Each system states a maximum height. We check your floor-to-ceiling height against it during design.
Usually through a slim framed door set into the run, chosen so the combination is covered by evidence.
Yes. We survey and install in Nelson and across Lancashire, including the BB9 district and nearby Colne.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
A survey in Nelson confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.