Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →From the SO45 district outwards, we arrange frameless fire-rated glazing for buildings across Hythe, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire-rated glazing is a glass wall where panes meet edge to edge with a tested sealant joint instead of vertical frames, held in discreet head and base channels. It gives an almost uninterrupted view while still being tested to resist fire.
Frameless glass is exposed during the build. We plan protection until other trades finish.
True frameless fire doors are rare; most frameless walls use a slim framed door within the run. We show you the options on drawings.
Maximum heights and the ability to form corners vary by system. Corners may need a post or a specific tested joint.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Coverage around Hythe includes the SO45, SO19 districts and nearby Southampton, Totton, Eastleigh. Hythe lies roughly 5 km from Southampton, within our Hampshire coverage.
We can phase work in Hythe around residents, staff or pupils, with out-of-hours options.
Every quote in Hythe identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Hythe budgets are not open-ended.
Frameless fire-rated glazing applies to many building types in Hythe, including public buildings and blocks of flats.
Each system states a maximum height. We check your floor-to-ceiling height against it during design.
Yes, typically. It also needs more careful site protection.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Survey timing in Hythe depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Hythe and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.