Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →Our frameless fire-rated glazing service covers Welling and neighbouring areas such as Bexley and Eltham, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire glazing only works within tight, tested limits: specific glass types, joint widths, sealants, channel details and maximum heights. We specify it where the evidence supports your layout, and tell you plainly when a slim framed system is the better route.
Coverage around Welling includes the DA16, DA6, DA7, DA15, SE2, DA5 districts and nearby Bexley, Eltham, Thamesmead. We cover Welling as part of our Greater London coverage.
Channels at the head have to allow for slab movement without loading the glass.
Frameless fire glazing is at the top of the price range because of the glass and precision required.
Frameless glass is exposed during the build. We plan protection until other trades finish.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Every quote in Welling identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Welling budgets are not open-ended.
Frameless fire-rated glazing applies to many building types in Welling, including student accommodation and retail and leisure units.
Each system states a maximum height. We check your floor-to-ceiling height against it during design.
Usually through a slim framed door set into the run, chosen so the combination is covered by evidence.
Survey timing in Welling depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Yes. We survey and install in Welling and across Greater London, including the DA16 district and nearby Bexley.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Welling and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.