Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →When a fire strategy, inspection report or building control comment in Hornchurch calls for glazing tested to resist fire, our frameless fire-rated glazing service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire glazing only works within tight, tested limits: specific glass types, joint widths, sealants, channel details and maximum heights. We specify it where the evidence supports your layout, and tell you plainly when a slim framed system is the better route.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
After survey you get a fixed written quote for the agreed scope, so Hornchurch budgets are not open-ended.
Every quote in Hornchurch identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Channels at the head have to allow for slab movement without loading the glass.
True frameless fire doors are rare; most frameless walls use a slim framed door within the run. We show you the options on drawings.
Frameless glass is exposed during the build. We plan protection until other trades finish.
Our Greater London coverage takes in Hornchurch (RM11, RM12, RM7, RM1, RM2, RM10) and the neighbouring towns of Romford, Dagenham, Becontree. Hornchurch sits within our Greater London coverage, alongside Romford.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover healthcare buildings, offices and other buildings in Hornchurch.
Each system states a maximum height. We check your floor-to-ceiling height against it during design.
Yes, using tested butt-jointed systems, usually with insulating glass. It must be installed exactly to the tested details.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Hornchurch to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.