Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · SW6

Frameless Fire-Rated Glazing in Fulham

From the SW6 district outwards, we arrange frameless fire-rated glazing for buildings across Fulham, matching glass, frames and seals to tested evidence rather than guesswork.

E 30 – EI 60SW6England

Quote for Fulham

Tell us what you need. We reply with next steps and a guide price.

Frameless Fire-Rated Glazing in Fulham: what's included

Frameless fire-rated glazing is a glass wall where panes meet edge to edge with a tested sealant joint instead of vertical frames, held in discreet head and base channels. It gives an almost uninterrupted view while still being tested to resist fire.

  • Rated sealant joints
  • Manifestation design
  • Tested butt-jointed insulating or integrity glass systems
  • Frameless-look fire doors where tested

Key checks for Fulham projects

Deflection

Channels at the head have to allow for slab movement without loading the glass.

Protection on site

Frameless glass is exposed during the build. We plan protection until other trades finish.

Doors

True frameless fire doors are rare; most frameless walls use a slim framed door within the run. We show you the options on drawings.

Fulham coverage and nearby towns

We cover Fulham and the surrounding postcode districts, including SW6, SW5, W6, W14, SW10, W8. Nearby towns we also serve include Chelsea, Putney, Battersea. We cover Fulham as part of our Greater London coverage.

What you can expect in Fulham

Work around occupied buildings

We can phase work in Fulham around residents, staff or pupils, with out-of-hours options.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Honest about unknowns

If an existing frame in a Fulham building has no traceable evidence, we say so and price the options rather than guess.

Which rules apply to frameless fire-rated glazing in Fulham?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.

Sectors we cover in Fulham

Frameless fire-rated glazing applies to many building types in Fulham, including hotels and public buildings.

Questions about frameless fire-rated glazing in Fulham

Is frameless fire-rated glass possible?

Yes, using tested butt-jointed systems, usually with insulating glass. It must be installed exactly to the tested details.

Is frameless more expensive than framed?

Yes, typically. It also needs more careful site protection.

Do you carry out frameless fire-rated glazing in Fulham?

Yes. We survey and install in Fulham and across Greater London, including the SW6 district and nearby Chelsea.

Do you work on occupied buildings in Fulham?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Related

Related services in Fulham

E 30 – EI 120

Fire-Rated Glazed Screens

Internal glazed screens that keep compartments and corridors protected.

Learn more →
Process

How a Fulham job runs

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Measure and check

We measure each opening in Fulham and check what the existing frames can accept.

Written quote

You receive a written quote naming the tested system and classification.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote