Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →When a fire strategy, inspection report or building control comment in Finchley calls for glazing tested to resist fire, our frameless fire-rated glazing service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire-rated glazing is a glass wall where panes meet edge to edge with a tested sealant joint instead of vertical frames, held in discreet head and base channels. It gives an almost uninterrupted view while still being tested to resist fire.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
You receive the classification references, glass marks and installation photographs for your fire safety records.
After survey you get a fixed written quote for the agreed scope, so Finchley budgets are not open-ended.
Maximum heights and the ability to form corners vary by system. Corners may need a post or a specific tested joint.
Channels at the head have to allow for slab movement without loading the glass.
True frameless fire doors are rare; most frameless walls use a slim framed door within the run. We show you the options on drawings.
Whether the building is in central Finchley or the wider N3, NW4, N12, NW7, NW11, N2 districts, we can survey and quote. We also cover Muswell Hill, Cricklewood, Kilburn. We cover Finchley as part of our Greater London coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Frameless fire-rated glazing applies to many building types in Finchley, including hotels and public buildings.
Each system states a maximum height. We check your floor-to-ceiling height against it during design.
Yes, typically. It also needs more careful site protection.
Yes. We survey and install in Finchley and across Greater London, including the N3 district and nearby Muswell Hill.
Building work in Finchley follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Finchley and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.