Fire-Rated Glass Partitions
Office glass partitions where the wall has to be fire-resisting.
Learn more →We provide frameless fire-rated glazing in Plymstock and across Devon, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
Frameless fire glazing only works within tight, tested limits: specific glass types, joint widths, sealants, channel details and maximum heights. We specify it where the evidence supports your layout, and tell you plainly when a slim framed system is the better route.
The sealant, joint width and any interlayer in the joint come from the test. Generic silicone in a fire glass joint is not acceptable.
Channels at the head have to allow for slab movement without loading the glass.
Maximum heights and the ability to form corners vary by system. Corners may need a post or a specific tested joint.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We cover Plymstock and the surrounding postcode districts, including PL9, PL2, PL4, PL3. Nearby towns we also serve include Plymouth, Paignton, Newton Abbot. Plymstock is about 4 km from Plymouth, the largest town in our Devon coverage.
You receive the classification references, glass marks and installation photographs for your fire safety records.
After survey you get a fixed written quote for the agreed scope, so Plymstock budgets are not open-ended.
We can phase work in Plymstock around residents, staff or pupils, with out-of-hours options.
Sector guides below cover industrial units, offices and other buildings in Plymstock.
Yes, typically. It also needs more careful site protection.
Yes, using tested butt-jointed systems, usually with insulating glass. It must be installed exactly to the tested details.
Yes. We survey and install in Plymstock and across Devon, including the PL9 district and nearby Plymouth.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Office glass partitions where the wall has to be fire-resisting.
Learn more →EI 30 to EI 120 glass that blocks heat as well as flames.
Learn more →Internal glazed screens that keep compartments and corridors protected.
Learn more →Doorsets with large glazed panels, tested as complete units.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Plymstock to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.