Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →When a fire strategy, inspection report or building control comment in Chichester calls for glazing tested to resist fire, our fire-rated fanlights and side panels service covers survey, supply and installation.
Tell us what you need. We reply with next steps and a guide price.
These panels are common in flat entrance doors, communal corridors, schools and older buildings, and they are often found glazed with ordinary glass. We survey them, replace unsuitable glass, correct beads and seals, and supply complete rated frames where the existing frame cannot be upgraded.
We can phase work in Chichester around residents, staff or pupils, with out-of-hours options.
After survey you get a fixed written quote for the agreed scope, so Chichester budgets are not open-ended.
If an existing frame in a Chichester building has no traceable evidence, we say so and price the options rather than guess.
If the existing frame can be shown to be suitable, new glass and seals may be enough; otherwise a complete rated frame is the reliable answer.
Grilles or openings in fanlights must be fire-rated or removed if the wall is fire-resisting.
In blocks of flats, the glazing around flat entrance doors forms part of the protection of the common parts and needs to match the door's performance.
Our West Sussex coverage takes in Chichester (PO19, PO20) and the neighbouring towns of Bognor Regis, Havant, Littlehampton. Chichester is about 52 km from Crawley, the largest town in our West Sussex coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Fire-rated fanlights and side panels applies to many building types in Chichester, including retail and leisure units and industrial units.
If the wall or door assembly is fire-resisting, yes. Ordinary glass above or beside a fire door creates a weak point.
Sometimes, if the existing frame is suitable. We check the frame before recommending glass-only replacement.
Building work in Chichester follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We survey and install in Chichester and across West Sussex, including the PO19 district and nearby Bognor Regis.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Chichester and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Installation to the system details, then a handover pack with photographs and evidence.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.