Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →Our fire-rated fanlights and side panels service covers Perth and neighbouring areas such as Glenrothes and Dundee, with every job built around a tested system.
Tell us what you need. We reply with next steps and a guide price.
Fanlights, side panels and borrowed lights are the glazed panels above and beside doors, or set into internal walls to share daylight between rooms. Where the wall or door around them is fire-resisting, the glazing must be fire-rated too, or it becomes the weak point.
Every quote in Perth identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
If an existing frame in a Perth building has no traceable evidence, we say so and price the options rather than guess.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Internal windows between rooms and corridors are a frequent survey finding in older offices and schools.
Side panels near doors fall in critical locations for impact safety, so the fire glass must also have the right impact classification.
If the existing frame can be shown to be suitable, new glass and seals may be enough; otherwise a complete rated frame is the reliable answer.
Coverage around Perth includes the PH1 districts and nearby Glenrothes, Dundee, Kirkcaldy. Dundee, around 29 km from Perth, is the largest town in the same coverage area.
In Scotland, building work needs a building warrant under the Building (Scotland) Regulations 2004, with fire guidance in Section 2 of the Building Standards Technical Handbooks rather than Approved Documents.
For relevant premises, the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 place duties on the duty holder to maintain fire safety measures, which include fire-resisting glazing.
Scottish guidance has its own approach to escape routes and compartmentation, so glazing designs are checked against the Technical Handbooks and the warrant drawings.
Sector guides below cover public buildings, care homes and other buildings in Perth.
Yes. Glass within 300mm of a door edge and below 1500mm is a critical location for impact safety.
An internal window that shares daylight between rooms or with a corridor. In a fire-resisting wall it must be fire-rated.
Survey timing in Perth depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Perth to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.