Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →If a building in Telford needs fire-rated fanlights and side panels, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.
Tell us what you need. We reply with next steps and a guide price.
Fanlights, side panels and borrowed lights are the glazed panels above and beside doors, or set into internal walls to share daylight between rooms. Where the wall or door around them is fire-resisting, the glazing must be fire-rated too, or it becomes the weak point.
Internal windows between rooms and corridors are a frequent survey finding in older offices and schools.
Fanlights and side panels can be missed when fire doors are upgraded, leaving ordinary glass beside a new fire door.
If the existing frame can be shown to be suitable, new glass and seals may be enough; otherwise a complete rated frame is the reliable answer.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
We cover Telford and the surrounding postcode districts, including TF3, TF4, TF2, TF1, TF7. Nearby towns we also serve include Wellington, Shrewsbury, Wolverhampton. Telford is the largest town in our Shropshire coverage.
We can phase work in Telford around residents, staff or pupils, with out-of-hours options.
You receive the classification references, glass marks and installation photographs for your fire safety records.
After survey you get a fixed written quote for the agreed scope, so Telford budgets are not open-ended.
Sector guides below cover healthcare buildings, schools and colleges and other buildings in Telford.
Yes. Glass within 300mm of a door edge and below 1500mm is a critical location for impact safety.
If the wall or door assembly is fire-resisting, yes. Ordinary glass above or beside a fire door creates a weak point.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Yes. We survey and install in Telford and across Shropshire, including the TF3 district and nearby Wellington.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We visit Telford to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.