Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →For Greenock buildings, we supply, replace and check fire-rated fanlights and side panels wherever the fire strategy depends on it, working to the tested system rather than the glass alone.
Tell us what you need. We reply with next steps and a guide price.
These panels are common in flat entrance doors, communal corridors, schools and older buildings, and they are often found glazed with ordinary glass. We survey them, replace unsuitable glass, correct beads and seals, and supply complete rated frames where the existing frame cannot be upgraded.
Survey visits can be arranged anywhere in Greenock, including the PA16, PA15, PA19 districts, and in nearby Vale of Leven, Clydebank, Paisley. Greenock is about 24 km from Paisley, the largest town in our Renfrewshire and Inverclyde coverage.
Fanlights and side panels can be missed when fire doors are upgraded, leaving ordinary glass beside a new fire door.
Side panels near doors fall in critical locations for impact safety, so the fire glass must also have the right impact classification.
Grilles or openings in fanlights must be fire-rated or removed if the wall is fire-resisting.
In Scotland, building work needs a building warrant under the Building (Scotland) Regulations 2004, with fire guidance in Section 2 of the Building Standards Technical Handbooks rather than Approved Documents.
For relevant premises, the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 place duties on the duty holder to maintain fire safety measures, which include fire-resisting glazing.
Scottish guidance has its own approach to escape routes and compartmentation, so glazing designs are checked against the Technical Handbooks and the warrant drawings.
If an existing frame in a Greenock building has no traceable evidence, we say so and price the options rather than guess.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Every quote in Greenock identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
We can survey and quote for retail and leisure units, hotels and other building types in Greenock.
Yes. Glass within 300mm of a door edge and below 1500mm is a critical location for impact safety.
If the wall or door assembly is fire-resisting, yes. Ordinary glass above or beside a fire door creates a weak point.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Yes. We survey and install in Greenock and across Renfrewshire and Inverclyde, including the PA16 district and nearby Vale of Leven.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
A survey in Greenock confirms sizes, access, existing evidence and fixing conditions.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.