Fanlights, side panels and borrowed lights are the glazed panels above and beside doors, or set into internal walls to share daylight between rooms. Where the wall or door around them is fire-resisting, the glazing must be fire-rated too, or it becomes the weak point.
If the existing frame can be shown to be suitable, new glass and seals may be enough; otherwise a complete rated frame is the reliable answer.
Internal windows between rooms and corridors are a frequent survey finding in older offices and schools.
Fanlights and side panels can be missed when fire doors are upgraded, leaving ordinary glass beside a new fire door.
Coverage around Deal includes the CT14 districts and nearby Dover, Ramsgate, Broadstairs. Deal is about 62 km from Maidstone, the largest town in our Kent coverage.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
You receive the classification references, glass marks and installation photographs for your fire safety records.
If an existing frame in a Deal building has no traceable evidence, we say so and price the options rather than guess.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover industrial units, public buildings and other buildings in Deal.
Sometimes, if the existing frame is suitable. We check the frame before recommending glass-only replacement.
If the wall or door assembly is fire-resisting, yes. Ordinary glass above or beside a fire door creates a weak point.
Building work in Deal follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We measure each opening in Deal and check what the existing frames can accept.
We set out the system, glass, evidence and programme, with a fixed price.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.