Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →From the SP10 district outwards, we arrange fire-rated fanlights and side panels for buildings across Andover, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
These panels are common in flat entrance doors, communal corridors, schools and older buildings, and they are often found glazed with ordinary glass. We survey them, replace unsuitable glass, correct beads and seals, and supply complete rated frames where the existing frame cannot be upgraded.
If an existing frame in a Andover building has no traceable evidence, we say so and price the options rather than guess.
After survey you get a fixed written quote for the agreed scope, so Andover budgets are not open-ended.
Every quote in Andover identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Grilles or openings in fanlights must be fire-rated or removed if the wall is fire-resisting.
Internal windows between rooms and corridors are a frequent survey finding in older offices and schools.
In blocks of flats, the glazing around flat entrance doors forms part of the protection of the common parts and needs to match the door's performance.
Survey visits can be arranged anywhere in Andover, including the SP10, SP11 districts, and in nearby Winchester, Newbury, Salisbury. Southampton, around 35 km from Andover, is the largest town in the same coverage area.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
We can survey and quote for care homes, offices and other building types in Andover.
If the wall or door assembly is fire-resisting, yes. Ordinary glass above or beside a fire door creates a weak point.
Yes. Glass within 300mm of a door edge and below 1500mm is a critical location for impact safety.
Survey timing in Andover depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Building work in Andover follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Andover and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.