Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →Looking for fire-rated fanlights and side panels in Highbury? We survey, supply and install tested fire-rated glazing for student accommodation, schools and colleges and other buildings in and around Highbury, including the N5 postcode district.
Tell us what you need. We reply with next steps and a guide price.
These panels are common in flat entrance doors, communal corridors, schools and older buildings, and they are often found glazed with ordinary glass. We survey them, replace unsuitable glass, correct beads and seals, and supply complete rated frames where the existing frame cannot be upgraded.
We can phase work in Highbury around residents, staff or pupils, with out-of-hours options.
You receive the classification references, glass marks and installation photographs for your fire safety records.
Every quote in Highbury identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Fanlights and side panels can be missed when fire doors are upgraded, leaving ordinary glass beside a new fire door.
Side panels near doors fall in critical locations for impact safety, so the fire glass must also have the right impact classification.
Grilles or openings in fanlights must be fire-rated or removed if the wall is fire-resisting.
Whether the building is in central Highbury or the wider N5, N7, N1, EC50, N1C, N4 districts, we can survey and quote. We also cover Islington, Holloway, Stamford Hill. We cover Highbury as part of our Greater London coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Sector guides below cover student accommodation, schools and colleges and other buildings in Highbury.
Sometimes, if the existing frame is suitable. We check the frame before recommending glass-only replacement.
An internal window that shares daylight between rooms or with a corridor. In a fire-resisting wall it must be fire-rated.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Building work in Highbury follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Highbury and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.