Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →Fire-rated fanlights and side panels in Cricklewood is usually needed for one of three reasons: new building work, a change to an existing fire-resisting wall, or defects found in an inspection. We handle all three.
Tell us what you need. We reply with next steps and a guide price.
Fanlights, side panels and borrowed lights are the glazed panels above and beside doors, or set into internal walls to share daylight between rooms. Where the wall or door around them is fire-resisting, the glazing must be fire-rated too, or it becomes the weak point.
If the existing frame can be shown to be suitable, new glass and seals may be enough; otherwise a complete rated frame is the reliable answer.
Side panels near doors fall in critical locations for impact safety, so the fire glass must also have the right impact classification.
Fanlights and side panels can be missed when fire doors are upgraded, leaving ordinary glass beside a new fire door.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Our Greater London coverage takes in Cricklewood (NW2, NW6, NW11, NW10, NW3, W10) and the neighbouring towns of Kilburn, Willesden, Chalk Farm. Cricklewood sits within our Greater London coverage, alongside Kilburn.
After survey you get a fixed written quote for the agreed scope, so Cricklewood budgets are not open-ended.
Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.
Every quote in Cricklewood identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Sector guides below cover retail and leisure units, hotels and other buildings in Cricklewood.
Yes. Glass within 300mm of a door edge and below 1500mm is a critical location for impact safety.
Sometimes, if the existing frame is suitable. We check the frame before recommending glass-only replacement.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Survey timing in Cricklewood depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
A survey in Cricklewood confirms sizes, access, existing evidence and fixing conditions.
We set out the system, glass, evidence and programme, with a fixed price.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.