Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Greater London · SE3

Fanlights, Side Panels & Borrowed Lights for Blackheath buildings

We provide fire-rated fanlights and side panels in Blackheath and across Greater London, working from the classification your building needs and handing over the evidence that proves what was fitted.

30 / 60 minSE3England

Quote for Blackheath

Tell us what you need. We reply with next steps and a guide price.

Fanlights, Side Panels & Borrowed Lights in Blackheath: what's included

These panels are common in flat entrance doors, communal corridors, schools and older buildings, and they are often found glazed with ordinary glass. We survey them, replace unsuitable glass, correct beads and seals, and supply complete rated frames where the existing frame cannot be upgraded.

  • Borrowed lights in fire-resisting walls
  • Records for your fire safety file
  • Glass, beads and seals to the frame evidence
  • Complete replacement frames where needed

Areas we cover around Blackheath

Whether the building is in central Blackheath or the wider SE3, SE13, SE10, SE12, SE8, SE7 districts, we can survey and quote. We also cover Greenwich, Catford, Eltham. Blackheath is one of the Greater London districts we cover.

Before you order fire-rated fanlights and side panels: what matters

Impact safety

Side panels near doors fall in critical locations for impact safety, so the fire glass must also have the right impact classification.

Flat entrance doors

In blocks of flats, the glazing around flat entrance doors forms part of the protection of the common parts and needs to match the door's performance.

Borrowed lights

Internal windows between rooms and corridors are a frequent survey finding in older offices and schools.

Fire glazing rules in England

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

What every Blackheath quote includes

Evidence you can file

You receive the classification references, glass marks and installation photographs for your fire safety records.

Rated systems, not just rated glass

Every quote in Blackheath identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Sectors we cover in Blackheath

We can survey and quote for public buildings, offices and other building types in Blackheath.

Fanlights, Side Panels & Borrowed Lights: Blackheath questions

Do side panels need safety glass too?

Yes. Glass within 300mm of a door edge and below 1500mm is a critical location for impact safety.

What is a borrowed light?

An internal window that shares daylight between rooms or with a corridor. In a fire-resisting wall it must be fire-rated.

Do you work on occupied buildings in Blackheath?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Which rules apply to fire-rated glazing in Blackheath?

Building work in Blackheath follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Blackheath

to door rating

Fire Door Vision Panels

Replacement and new vision panels fitted to the door's evidence.

Learn more →
Process

How a Blackheath job runs

Start with the brief

Tell us the rating required, sizes and building type, or ask us to find out.

Survey

We visit Blackheath to measure, record existing marks and check the frames and substrate.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Complete and document

Work is completed to the manufacturer's details and documented for your records.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote