Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →We provide fire-rated fanlights and side panels in Portslade and across East Sussex, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
These panels are common in flat entrance doors, communal corridors, schools and older buildings, and they are often found glazed with ordinary glass. We survey them, replace unsuitable glass, correct beads and seals, and supply complete rated frames where the existing frame cannot be upgraded.
In blocks of flats, the glazing around flat entrance doors forms part of the protection of the common parts and needs to match the door's performance.
Side panels near doors fall in critical locations for impact safety, so the fire glass must also have the right impact classification.
Internal windows between rooms and corridors are a frequent survey finding in older offices and schools.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Whether the building is in central Portslade or the wider BN41, BN42, BN3, BN43 districts, we can survey and quote. We also cover Hove, Brighton, Worthing. Portslade is about 6 km from Brighton, the largest town in our East Sussex coverage.
After survey you get a fixed written quote for the agreed scope, so Portslade budgets are not open-ended.
You receive the classification references, glass marks and installation photographs for your fire safety records.
If an existing frame in a Portslade building has no traceable evidence, we say so and price the options rather than guess.
Fire-rated fanlights and side panels applies to many building types in Portslade, including schools and colleges and retail and leisure units.
If the wall or door assembly is fire-resisting, yes. Ordinary glass above or beside a fire door creates a weak point.
Yes. Glass within 300mm of a door edge and below 1500mm is a critical location for impact safety.
Survey timing in Portslade depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Portslade and check what the existing frames can accept.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.