Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →We provide fire-rated fanlights and side panels in Poole and across Dorset, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
Fanlights, side panels and borrowed lights are the glazed panels above and beside doors, or set into internal walls to share daylight between rooms. Where the wall or door around them is fire-resisting, the glazing must be fire-rated too, or it becomes the weak point.
We can phase work in Poole around residents, staff or pupils, with out-of-hours options.
If an existing frame in a Poole building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Poole identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Side panels near doors fall in critical locations for impact safety, so the fire glass must also have the right impact classification.
In blocks of flats, the glazing around flat entrance doors forms part of the protection of the common parts and needs to match the door's performance.
Grilles or openings in fanlights must be fire-rated or removed if the wall is fire-resisting.
Survey visits can be arranged anywhere in Poole, including the BH15, BH14, BH17, BH18, BH13 districts, and in nearby Bournemouth, Christchurch, New Milton. Bournemouth, around 7 km from Poole, is the largest town in the same coverage area.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
Fire-rated fanlights and side panels applies to many building types in Poole, including hotels and student accommodation.
Yes. Glass within 300mm of a door edge and below 1500mm is a critical location for impact safety.
An internal window that shares daylight between rooms or with a corridor. In a fire-resisting wall it must be fire-rated.
Building work in Poole follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Tell us the rating required, sizes and building type, or ask us to find out.
We visit Poole to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.