Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →We provide fire-rated fanlights and side panels in Craigavon and across County Armagh, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
These panels are common in flat entrance doors, communal corridors, schools and older buildings, and they are often found glazed with ordinary glass. We survey them, replace unsuitable glass, correct beads and seals, and supply complete rated frames where the existing frame cannot be upgraded.
Internal windows between rooms and corridors are a frequent survey finding in older offices and schools.
Side panels near doors fall in critical locations for impact safety, so the fire glass must also have the right impact classification.
Grilles or openings in fanlights must be fire-rated or removed if the wall is fire-resisting.
In Northern Ireland, building work follows the Building Regulations (Northern Ireland) 2012, with fire safety guidance in Technical Booklet E, approved by the district council's building control.
Once in use, the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 require the appropriate person to maintain fire safety measures, including fire-resisting glazing.
Technical Booklet E sets its own provisions for glazing on escape routes, so designs are checked against the Northern Ireland guidance rather than English documents.
We cover Craigavon and the surrounding postcode districts, including BT62, BT65, BT64, BT66. Nearby towns we also serve include Portadown, Lisburn, Newry. Craigavon is the largest town in our County Armagh coverage.
Every quote in Craigavon identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Craigavon budgets are not open-ended.
We can phase work in Craigavon around residents, staff or pupils, with out-of-hours options.
Fire-rated fanlights and side panels applies to many building types in Craigavon, including schools and colleges and care homes.
Yes. Glass within 300mm of a door edge and below 1500mm is a critical location for impact safety.
An internal window that shares daylight between rooms or with a corridor. In a fire-resisting wall it must be fire-rated.
Survey timing in Craigavon depends on access, the size of the building and how urgent the defect is. Tell us your deadline when you enquire and we will confirm a date before you commit.
Craigavon is in Northern Ireland, where the Building Regulations (NI) 2012 and Technical Booklet E apply, with the Fire Safety Regulations (NI) 2010 covering occupied premises.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit Craigavon to measure, record existing marks and check the frames and substrate.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.