Fire Door Vision Panels
Replacement and new vision panels fitted to the door's evidence.
Learn more →We provide fire-rated fanlights and side panels in Ayr and across Ayrshire, working from the classification your building needs and handing over the evidence that proves what was fitted.
Tell us what you need. We reply with next steps and a guide price.
These panels are common in flat entrance doors, communal corridors, schools and older buildings, and they are often found glazed with ordinary glass. We survey them, replace unsuitable glass, correct beads and seals, and supply complete rated frames where the existing frame cannot be upgraded.
In blocks of flats, the glazing around flat entrance doors forms part of the protection of the common parts and needs to match the door's performance.
Internal windows between rooms and corridors are a frequent survey finding in older offices and schools.
Side panels near doors fall in critical locations for impact safety, so the fire glass must also have the right impact classification.
In Scotland, building work needs a building warrant under the Building (Scotland) Regulations 2004, with fire guidance in Section 2 of the Building Standards Technical Handbooks rather than Approved Documents.
For relevant premises, the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 place duties on the duty holder to maintain fire safety measures, which include fire-resisting glazing.
Scottish guidance has its own approach to escape routes and compartmentation, so glazing designs are checked against the Technical Handbooks and the warrant drawings.
Survey visits can be arranged anywhere in Ayr, including the KA7, KA8, KA9 districts, and in nearby Irvine, Kilmarnock, Newton Mearns. Ayr lies roughly 19 km from Kilmarnock, within our Ayrshire coverage.
After survey you get a fixed written quote for the agreed scope, so Ayr budgets are not open-ended.
Every quote in Ayr identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Designs follow the building and fire safety rules that apply in Scotland, not a one-size-fits-all approach.
Sector guides below cover hotels, care homes and other buildings in Ayr.
If the wall or door assembly is fire-resisting, yes. Ordinary glass above or beside a fire door creates a weak point.
Sometimes, if the existing frame is suitable. We check the frame before recommending glass-only replacement.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Replacement and new vision panels fitted to the door's evidence.
Learn more →Hardwood screens and borrowed lights tested for fire.
Learn more →Putting right the defects found in surveys and fire risk assessments.
Learn more →Replace old Georgian wired glass with modern fire glass.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We visit Ayr to measure, record existing marks and check the frames and substrate.
You receive a written quote naming the tested system and classification.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.