Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
West Sussex · RH16

Fire-Rated Curtain Walling across Haywards Heath

We provide fire-rated curtain walling in Haywards Heath and across West Sussex, working from the classification your building needs and handing over the evidence that proves what was fitted.

E 30 – EI 60RH16England

Quote for Haywards Heath

Tell us what you need. We reply with next steps and a guide price.

What our fire-rated curtain walling service includes in Haywards Heath

Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.

  • Slab-edge fire-stopping and cavity barriers to the design
  • Tested fire-rated curtain wall systems
  • External-grade fire glass
  • Spandrel and opaque panel coordination

Where we work around Haywards Heath

Coverage around Haywards Heath includes the RH16, RH17, RH15 districts and nearby Burgess Hill, Crawley, East Grinstead. Crawley, around 14 km from Haywards Heath, is the largest town in the same coverage area.

What to check before ordering fire-rated curtain walling in Haywards Heath

Higher-risk buildings

Work on higher-risk residential buildings in England goes through the Building Safety Regulator, which needs full product evidence at the design stage.

Boundaries

External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.

Thermal and acoustic

Fire-rated units can still meet thermal targets when specified correctly; we confirm U-values with the system supplier.

Which rules apply to fire-rated curtain walling in Haywards Heath?

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

What every Haywards Heath quote includes

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Haywards Heath budgets are not open-ended.

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Rated systems, not just rated glass

Every quote in Haywards Heath identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.

Sectors we cover in Haywards Heath

We can survey and quote for blocks of flats, hotels and other building types in Haywards Heath.

FAQs for Haywards Heath

Can fire glass be used in double-glazed units?

Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.

When does curtain walling need to be fire-rated?

Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.

Do you work on occupied buildings in Haywards Heath?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Which rules apply to fire-rated glazing in Haywards Heath?

Building work in Haywards Heath follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.

Related

Related services in Haywards Heath

E 30 – EI 60

Fire-Rated Windows

Windows near boundaries and protected routes, tested for fire.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

How a Haywards Heath job runs

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Site visit

A survey in Haywards Heath confirms sizes, access, existing evidence and fixing conditions.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Install and hand over

Installation to the system details, then a handover pack with photographs and evidence.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote