Fire-Rated Windows
Windows near boundaries and protected routes, tested for fire.
Learn more →Looking for fire-rated curtain walling in Gorseinon? We survey, supply and install tested fire-rated glazing for blocks of flats, care homes and other buildings in and around Gorseinon, including the SA4 postcode district.
Tell us what you need. We reply with next steps and a guide price.
We supply and install fire-rated curtain walling and fire-rated zones within standard curtain walling, alongside the fire-stopping at slab edges. External wall work is closely scrutinised after recent regulatory changes, so every element we fit is backed by evidence for its position.
External fire glass must be suitable for UV and weather exposure, usually in a sealed double-glazed unit with the fire pane positioned as tested.
The gap between the curtain wall and each floor slab needs fire-stopping designed with the facade, not added afterwards.
External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.
Building regulations are devolved in Wales, so fire safety design follows the Welsh Ministers' version of Approved Document B rather than the English one, alongside impact safety guidance for glazing.
The Regulatory Reform (Fire Safety) Order 2005 applies in Wales, so the responsible person must maintain fire-resisting glazing as part of the premises' fire safety measures. The Fire Safety Act 2021 confirmed this extends to the structure, external walls and flat entrance doors of multi-occupied residential buildings.
Wales is introducing its own building safety regime for occupied residential buildings, so check current Welsh requirements before planning major works to blocks of flats.
Whether the building is in central Gorseinon or the wider SA4, SA5 districts, we can survey and quote. We also cover Llanelli, Swansea, Ammanford. Swansea, around 9 km from Gorseinon, is the largest town in the same coverage area.
If an existing frame in a Gorseinon building has no traceable evidence, we say so and price the options rather than guess.
Designs follow the building and fire safety rules that apply in Wales, not a one-size-fits-all approach.
Every quote in Gorseinon identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
Fire-rated curtain walling applies to many building types in Gorseinon, including blocks of flats and care homes.
We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.
Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
We can give a guide range from photos and sizes, including a clear photo of any marks on the glass. A fixed price follows a survey.
Windows near boundaries and protected routes, tested for fire.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send the fire strategy extract, inspection report or a few photos of the openings.
We measure each opening in Gorseinon and check what the existing frames can accept.
Your quote lists each item with its classification and the evidence it relies on.
Work is completed to the manufacturer's details and documented for your records.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.