Tested fire-rated glazing systemsSurvey, supply and install UK-wideEvidence pack on handover
0800 088 6248
FIRE-GLAZING
Tyne and Wear · NE28

Fire-Rated Curtain Walling — Wallsend and NE28

If a building in Wallsend needs fire-rated curtain walling, the starting point is the rating its fire strategy requires. We confirm that, survey the openings and quote a tested system to suit.

E 30 – EI 60NE28England

Quote for Wallsend

Tell us what you need. We reply with next steps and a guide price.

What's involved with fire-rated curtain walling in Wallsend

We supply and install fire-rated curtain walling and fire-rated zones within standard curtain walling, alongside the fire-stopping at slab edges. External wall work is closely scrutinised after recent regulatory changes, so every element we fit is backed by evidence for its position.

  • Handover evidence for the building record
  • Slab-edge fire-stopping and cavity barriers to the design
  • External-grade fire glass
  • Tested fire-rated curtain wall systems

Wallsend coverage and nearby towns

Our Tyne and Wear coverage takes in Wallsend (NE28, NE31, NE6, NE32, NE7, NE2) and the neighbouring towns of Hebburn, Jarrow, Felling. Wallsend lies roughly 5 km from Newcastle upon Tyne, within our Tyne and Wear coverage.

Before you order fire-rated curtain walling: what matters

Higher-risk buildings

Work on higher-risk residential buildings in England goes through the Building Safety Regulator, which needs full product evidence at the design stage.

Thermal and acoustic

Fire-rated units can still meet thermal targets when specified correctly; we confirm U-values with the system supplier.

Boundaries

External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.

England regulations that shape the job

England Which rules apply?

Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.

Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.

How we work in Wallsend

England rules applied

Designs follow the building and fire safety rules that apply in England, not a one-size-fits-all approach.

Work around occupied buildings

We can phase work in Wallsend around residents, staff or pupils, with out-of-hours options.

Fixed written quotes

After survey you get a fixed written quote for the agreed scope, so Wallsend budgets are not open-ended.

Wallsend building types

Sector guides below cover public buildings, hotels and other buildings in Wallsend.

FAQs for Wallsend

Can fire glass be used in double-glazed units?

Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.

When does curtain walling need to be fire-rated?

Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.

Do you work on occupied buildings in Wallsend?

Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.

Do you carry out fire-rated curtain walling in Wallsend?

Yes. We survey and install in Wallsend and across Tyne and Wear, including the NE28 district and nearby Hebburn.

Related

Related services in Wallsend

E 30 – EI 60

Fire-Rated Windows

Windows near boundaries and protected routes, tested for fire.

Learn more →
E · EW · EI

Fire Glazing Surveys

Surveys that identify what fire glazing you have and what needs fixing.

Learn more →
Process

How a Wallsend job runs

Tell us what you have

Send drawings, a fire risk assessment action or photos of the glass marks.

Survey

We visit Wallsend to measure, record existing marks and check the frames and substrate.

Written proposal

We set out the system, glass, evidence and programme, with a fixed price.

Fit and record

We install, photograph seals and fixings before closing up, and hand over the schedule.

Need fire-rated glazing checked, replaced or installed?

Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.

Call freeGet a quote