Fire-Rated Windows
Windows near boundaries and protected routes, tested for fire.
Learn more →From the RH2 district outwards, we arrange fire-rated curtain walling for buildings across Reigate, matching glass, frames and seals to tested evidence rather than guesswork.
Tell us what you need. We reply with next steps and a guide price.
Fire-rated curtain walling is a glazed facade system tested to resist fire, used where an external wall has to stop fire spreading to a neighbouring building, between floors, or past a protected stair or lobby. It combines facade performance, such as weather tightness and thermal values, with a fire classification.
If an existing frame in a Reigate building has no traceable evidence, we say so and price the options rather than guess.
Every quote in Reigate identifies the tested system: frame, glass, beads, seals and fixings, within its pane-size limits.
After survey you get a fixed written quote for the agreed scope, so Reigate budgets are not open-ended.
Fire-rated units can still meet thermal targets when specified correctly; we confirm U-values with the system supplier.
Work on higher-risk residential buildings in England goes through the Building Safety Regulator, which needs full product evidence at the design stage.
External walls close to a boundary may need to be fire-resisting with limited unprotected areas. Fixed glazing that meets the wall's full fire-resistance requirement, including insulation where required, is not counted as unprotected area, so it can let you keep glass in those positions.
We cover Reigate and the surrounding postcode districts, including RH2, RH3, RH1. Nearby towns we also serve include Redhill, Horley, Banstead. Reigate lies roughly 26 km from Woking, within our Surrey coverage.
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
We can survey and quote for care homes, industrial units and other building types in Reigate.
We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.
Yes. External fire-rated glazing is usually supplied as a sealed unit with the fire pane in a tested position.
Yes. We plan phasing, out-of-hours work and temporary protection so the building can stay in use where the fire strategy allows.
Building work in Reigate follows the Building Regulations 2010 and Approved Document B, and occupied buildings are covered by the Regulatory Reform (Fire Safety) Order 2005.
Windows near boundaries and protected routes, tested for fire.
Learn more →Light, modern aluminium framing tested for fire.
Learn more →E and EW glass where flames and hot gases must be stopped.
Learn more →Surveys that identify what fire glazing you have and what needs fixing.
Learn more →Send drawings, a fire risk assessment action or photos of the glass marks.
We measure each opening in Reigate and check what the existing frames can accept.
We set out the system, glass, evidence and programme, with a fixed price.
We install, photograph seals and fixings before closing up, and hand over the schedule.
Send sizes, photos of any glass marks or your inspection report and we will come back with the right tested system.