Fire-Rated Curtain Walling for Nottinghamshire buildings
We take fire-rated curtain walling enquiries from across Nottinghamshire, with surveys arranged in Nottingham, Mansfield, Worksop, Newark-on-Trent, Arnold and the surrounding towns.
Quote for Nottinghamshire
Tell us what you need. We reply with next steps and a guide price.

Fire-Rated Curtain Walling by town in Nottinghamshire
Nottinghamshire coverage includes Nottingham, Mansfield, Worksop, Newark-on-Trent, Arnold and the NG, DN, S postcode areas (27 postcode districts).
Fire-Rated Curtain Walling: what you get in Nottinghamshire
We supply and install fire-rated curtain walling and fire-rated zones within standard curtain walling, alongside the fire-stopping at slab edges. External wall work is closely scrutinised after recent regulatory changes, so every element we fit is backed by evidence for its position.
- Slab-edge fire-stopping and cavity barriers to the design
- Fire-rated zones within mixed facades
- Tested fire-rated curtain wall systems
Before you order in Nottinghamshire
External-grade glass
External fire glass must be suitable for UV and weather exposure, usually in a sealed double-glazed unit with the fire pane positioned as tested.
Combustibility rules
In England, materials in the external walls of relevant buildings 18 metres or more in height are restricted. We coordinate with the facade designer on every component.
Higher-risk buildings
Work on higher-risk residential buildings in England goes through the Building Safety Regulator, which needs full product evidence at the design stage.
England rules for fire glazing
England Which rules apply?
Building work in England is covered by the Building Regulations 2010, with fire safety guidance in Approved Document B and impact safety guidance for glazing in Approved Document K.
Once a building is in use, the Regulatory Reform (Fire Safety) Order 2005 requires the responsible person to maintain fire safety measures, including fire-resisting glazing. The Fire Safety (England) Regulations 2022 add duties for multi-occupied residential buildings, including fire door checks in buildings over 11 metres.
In higher-risk buildings, broadly 18 metres or seven storeys with two or more homes, the Building Safety Regulator is the building control authority. England is also phasing out BS 476 references from Approved Document B, with the remaining fire-resistance references due to go in September 2029.
Fire-Rated Curtain Walling in Nottinghamshire: questions
Do you work on high-rise buildings?
We can supply and install on taller buildings where the project has the required approvals, and we provide evidence suitable for the Building Safety Regulator in England.
When does curtain walling need to be fire-rated?
Typically where the facade is near a boundary, where it encloses a protected stair or lobby, or where fire spread between floors has to be controlled. The fire strategy sets the requirement.
Can you add fire-rated zones to existing curtain walling?
Sometimes, if the existing system has a tested fire-rated version. Otherwise a local replacement may be needed.
Which parts of Nottinghamshire do you cover?
All of it: Nottingham, Mansfield, Worksop, Newark-on-Trent, Arnold and every district in the NG, DN, S postcode areas.
Related services in Nottinghamshire
How a Nottinghamshire job runs
Share the details
Send the fire strategy extract, inspection report or a few photos of the openings.
Site visit
A survey in Nottinghamshire confirms sizes, access, existing evidence and fixing conditions.
Quote and evidence
Your quote lists each item with its classification and the evidence it relies on.
Fit and record
We install, photograph seals and fixings before closing up, and hand over the schedule.